DIGITAL SYSTEM AMPLIFIER
Owner‘s Manual 15
4 Options
Installing one of the optionally available extension modules in the extension slot on the rear panel lets you expand the power
amp’s functional range. As an example, the following paragraphs describe the RCM-810 Remote Control Module. Please
read and follow the instructions provided in the documentation that you have received together with each extension module.
4.1 RCM-810
System Description and Features
The RCM-810 Remote Control Module is a digital controller module for live sound reinforcement, PA and fixed installation
applications. Installing the RCM-810 turns a conventional amp into a remote amplifier, which, at any time, provides complete
overview of the overall system status and control of system parameters.
RCM-810 modules allow the integration of amplifiers into a remote control network with up to 100 devices. By using multiple
networks within an IRIS-Net project up to 250 amplifiers can be used in total. This offers the possibility to control and monitor
an entire PA system from one or more PCs using the IRIS-Net - Intelligent Remote & Integrated Supervision - software
package. All operational states, e.g. power-on status, temperature, activation of protections, load impedance, etc., are
centrally registered and displayed in IRIS-Net. This provides the possibility to react and to selectively intervene even before
critical operational states arise. Programming an automatic reaction, when specific thresholds are being exceeded or fallen
below, is also possible.
Parameters, like power on/off, muting, etc. can be controlled in real-time and stored in the amplifier. In the event of network
failure or loss of power, all settings stay intact, independent of the control by the network.
Furthermore, the RCM-810 provides a control port with freely programmable control inputs and control outputs. Control inputs
(GPI's) allow the connection of switches. IRIS-Net offers the possibility to program a variety of logic functions for the inputs.
Control outputs (GPO's) allow the connection of external components, which, for example, are used to signal specific states to
peripheral equipment. For further details about configuration, control and monitoring of amps with installed RCM-810
modules, please refer to the documentation of IRIS-Net. The latest version of IRIS-Net is available at www.dynacord.com.